Area riservata
Assistenza clienti

Wrasse climbing gourami amur pike Arctic char, steelhead sprat sea lamprey grunion. Walleye

Contacts
Location
523 Sylvan Ave, 5th Floor
Mountain View, CA 94041USA

Products

View filters
  • -

    Generator

    HL 5000 SE-3 AVR ATS

    HL 5000 SE-3 AVR ATS

    Three phase generating set with Diesel engine coupled to three phase 2-pole alternator with system voltage regulation AVR. Avviamento elettrico a batteria. Quadro di comando con 1 presa trifase CEE 16A, 1 presa monofase 16A e con caricabatteria 12 volt.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HL 8000 SE AVR

    HL 8000 SE AVR

    Single-phase generator set with Diesel engine, flanged to a single-phase 2-pole alternator. AVR voltage regulation system. Battery electric starting. Control panel with 1 single-phase CEE 16A outlet, 1 single-phase CEE 32A outlet and with 12-volt battery charger.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HL 8000 SE AVR ATS

    HL 8000 SE AVR ATS

    Gruppo elettrogeno monofase con motore Diesel, flangiato ad un alternatore a 2 poli monofase. Sistema di regolazione della tensione AVR. Avviamento elettrico a batteria. Control panel with 1 single phase CEE plug 16A, 1 single phase CEE plug 32A and 12 volt battery-charger.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HL 8000 SE-3 AVR

    HL 8000 SE-3 AVR

    Three phase generating set with Diesel engine coupled to three phase 2-pole alternator with system voltage regulation AVR. Avviamento elettrico a batteria. Quadro di comando con 1 presa trifase CEE 16A, 1 presa monofase 16A e con caricabatteria 12 volt.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HL 8000 SE-3 AVR ATS

    HL 8000 SE-3 AVR ATS

    Three phase generating set with Diesel engine coupled to three phase 2-pole alternator with system voltage regulation AVR. Electric starter with battery. Control panel with 1 three phase CEE plug 16A, 1 single phase plug 16A and 12 volt battery charger.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    GF 5500 CXE

    GF 5500 CXE

    Single phase generating set with Diesel engine coupled to single phase 2-pole alternator. System brushless with capacitor regulation. Recoil or electric starter with battery. Control panel with 1 single phase CEE plug 16A, 1 single phase CEE plug 32A and 12 volt battery-charger.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    GF 5500 CXE-3 AVR

    GF 5500 CXE-3 AVR

    Three phase generating set with Diesel engine coupled to three phase 2-pole alternator with system voltage regulation AVR. Recoil or electric starter with battery. Control panel with 1 three phase CEE 16 A plug, 1 single phase 16 A plug and 12 volt battery-charger.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HL 12000-E AVR

    HL 12000-E AVR

    Single phase generating set with Diesel engine coupled to single phase 2-pole alternator, with system voltage regulation AVR. Electric starter with battery. Control panel with 2 single phase CEE plug 32A and termic protector.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HL 12000-3E AVR

    HL 12000-3E AVR

    Three phase generating set with Diesel engine coupled to three phase 2-pole alternator, with system voltage regulation AVR. Electric starter with battery. Control panel with 1 three phase CEE plug 16A and 1 single-phase CEE plug 32A and termic protector.  

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 5000-E

    HS 5000-E

    Single phase generating set with Diesel engine coupled to single phase 2-pole NSM alternator. System brushless with capacitor regulation. Recoil or electric starter with battery. Control panel with 2 single phase CEE plugs 16A and 1 termic protector.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 5000-E AVR

    HS 5000-E AVR

    Single phase generating set with Diesel engine coupled to single phase 2-pole NSM alternator. With system voltage regulation AVR. Recoil or electric starter with battery. Control panel with 2 single phase CEE plugs 16A and 1 termic protector.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 6500-E

    HS 6500-E

    Single phase generating set with Diesel engine coupled to single phase 2-pole NSM alternator. System brushless with capacitor regulation. Recoil or electric starter with battery. Quadro di comando con 2 prese monofase CEE 16A e 2 protettori termici. Optional: pannello prese con 1 presa monofase CEE 32A, 1 presa monofase CEE 16A e 2 protettori termici.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 6500-E ATS

    HS 6500-E ATS

    Single phase generating set with Diesel engine coupled to single phase 2-pole alternator. System brushless with capacitor regulation. Recoil or electric starter with battery. Quadro di comando con 2 prese monofase CEE 16A e 2 protettori termici. Optional: pannello prese con 1 presa monofase CEE 32A, 1 presa monofase CEE 16A e 2 protettori termici.  

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 6500-E AVR

    HS 6500-E AVR

    Single phase generating set with Diesel engine coupled to single phase 2-pole NSM alternator with system voltage regulation AVR. Recoil or electric starter with battery. Control panel with 1 single phase CEE plug 16A, 1 single phase CEE plug 32A and 2 termic protectors.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 6500-E AVR ATS

    HS 6500-E AVR ATS

    Gruppo elettrogeno monofase con motore Diesel, flangiato ad un alternatore a 2 poli monofase con sistema di regolazione della tensione AVR. Recoil or electric starter with battery. Control panel with 1 single phase CEE plug 16A, 1 single phase CEE plug 32A and 2 termic protectors.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 6500-3E ATS

    HS 6500-3E ATS

    Gruppo elettrogeno trifase con motore Diesel, flangiato ad un alternatore a 2 poli trifase. Sistema di regolazione a spazzole compound. Recoil or electric starter with battery. Quadro di comando con 1 presa trifase CEE 16A, 1 presa monofase CEE 16A, protettore termico e voltometro.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 9000-E AVR

    HS 9000-E AVR

    Single-phase generating set with Diesel engine coupled to single-phase 2-pole NSM alternator. System voltage regulation AVR. Recoil or electric starter with battery. Control panel with 1 plug single-phase CEE plug 16A, 1 plug single phase CEE plug 32A, termic protector and voltmeter.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 9000-E AVR ATS

    HS 9000-E AVR ATS

    Gruppo elettrogeno monofase con motore Diesel, flangiato ad un alternatore a 2 poli monofase. Sistema di regolazione della tensione AVR. Recoil or electric starter with battery. Control panel with 1 single phase CEE plug 16A, 1 single phase CEE plug 32A and 2 termic protectors.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 6500-3E

    HS 6500-3E

    Three phase generating set with Diesel engine coupled to three phase 2-pole alternator. System brushes compound regulation. Recoil or electric starter with battery. Control panel with 1 plug three phase CEE plug 16A, 1 plug single phase CEE plug 16A, termic protector and voltmeter.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 9000-3E AVR ATS

    HS 9000-3E AVR ATS

    Gruppo elettrogeno trifase con motore Diesel, flangiato ad un alternatore a 2 poli trifase. Sistema di regolazione della tensione AVR. Recoil or electric starter with battery. Quadro di comando con 1 presa trifase CEE 16A, 1 presa monofase CEE 16A, protettore termico e voltometro.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 9000-3E AVR

    HS 9000-3E AVR

    Three phase/single-phase generating set with Diesel engine coupled to three phase/single-phase 2-pole NSM alternator. System voltage regulation AVR. Recoil or electric starter with battery. Control panel with 1 plug three phase CEE plug 16A, 1 plug single phase CEE plug 16A, termic protector.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 12000-E AVR

    HS 12000-E AVR

    Single phase generating set with Diesel engine coupled to single phase 2-pole NSM alternator. Control panel with 1 single phase CEE plug 16A, 1 single phase CEE plug 32A and 2 termic protectors.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 12000-3E

    HS 12000-3E

    Three phase/single-phase generating set with Diesel engine coupled to three phase/single-phase 2 pole NSM alternator. System voltage regulation AVR. Electric starter with battery. Control panel with 1 hree phase CEE plug 32A, 1 single phase CEE plug 16A and termic protector.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 6500-SS AVR

    HS 6500-SS AVR

    Single phase generating set with silenced Diesel engine coupled to single phase 2-pole NSM alternator with system voltage regulation AVR. Electric starter with battery. Control panel with 2 plugs, one single phase CEE plug 16A and one single phase CEE plug 32A, termic protector and voltmeter.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 6500-SS AVR ATS

    HS 6500-SS AVR ATS

    Single phase generating set with silenced Diesel engine coupled to single phase 2-pole alternator with system voltage regulation AVR. Electric starter with battery. Control panel with 2 plugs, one single phase CEE plug 16A and one single phase CEE plug 32A, termic protector and voltmeter.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 6500 SS-3

    HS 6500 SS-3

    Three phase/single-phase generating set with silenced Diesel engine coupled to three phase/single-phase 2-pole NSM alternator. System brushes compound regulation. Avviamento elettrico a batteria. Control panel with 2 plugs, one three phase CEE plug 16A and one single phase CEE plug 16A, termic protector and voltmeter.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 6500 SS-3 ATS

    HS 6500 SS-3 ATS

    Three phase generating set with silenced Diesel engine coupled to three phase 2-pole alternator. System brushes compound regulation. Electric starter with battery. Control panel with 2 plugs, one three phase CEE plug 16A and one single phase CEE plug 16A, termic protector and voltmeter

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 9000-SS AVR

    HS 9000-SS AVR

    Single phase generating set with silenced diesel engine coupled to single phase 2-pole NSM alternator with system voltage regulation AVR, with control panel for automatic operate. Electric starter with battery. Control panel with 2 plugs, one single phase CEE plug 16A and one single phase CEE plug 32A, termic protector and voltmeter.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    HS 9000 SS-3

    HS 9000 SS-3

    Three phase/single-phase generating set with silenced diesel engine coupled to three phase/single-phase 2-pole NSM alternator. System brushes compound regulation, with control panel for automatic operate. Electric starter with battery. Control panel with 2 plugs, one three phase CEE plug 16A and one single phase CEE plug 16A, termic protector and voltmeter.

    Fuel: Diesel
    Starting system: Electric

  • -

    Generator

    AGS 16 KVA STAGE 5

    AGS 16 KVA STAGE 5

    Stationary silenced generating set with Diesel engine 1500 rpm with compound brush regulation system. Electric starting with battery predisposition for operation in ATS. Complete with: Automatic engine stop device - Voltmeter - hour meter - Earth leakage circuit breaker - Emergency stop button - Starter battery - Power output protection - fork lift pockets - central lifting eye 1 CEE 32A - 400V / 50Hz three-phase socket 1 CEE 16A - 400V / 50Hz three-phase socket 2 CEE 16A - 230 / 50Hz single-phase sockets

    Fuel: Diesel
    Starting system: Electric